Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 380...400 V AC kalem ; LC1K0910Q7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil...
VAT-exclusive price: 3.544,00 |
VAT-inclusive price: 4.252,80 |
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 380...400 V AC coil
range |
TeSys
|
|
---|---|---|
product or component type |
Contactor
|
|
product name |
TeSys K
|
|
device application |
Control
|
|
contactor application |
Motor control
Resistive load |
utilisation category |
AC-1
AC-4 AC-3 |
|
---|---|---|
poles description |
3P
|
|
power pole contact composition |
3 NO
|
|
[Ie] rated operational current |
20 A (at <50 °C) at <= 440 V AC AC-1 for power circuit
9 A at <= 440 V AC AC-3 for power circuit 16 A (at <70 °C) at 690 V AC AC-1 for power circuit |
|
control circuit type |
AC at 50/60 Hz
|
|
[Uc] control circuit voltage |
380...400 V AC 50/60 Hz
|
|
motor power kW |
2.2 kW at 220...230 V AC 50/60 Hz AC-3
4 kW at 380...415 V AC 50/60 Hz AC-3 4 kW at 440 V AC 50/60 Hz AC-3 4 kW at 480 V AC 50/60 Hz AC-3 4 kW at 500...600 V AC 50/60 Hz AC-3 4 kW at 660...690 V AC 50/60 Hz AC-3 2.2 kW at 400 V AC 50/60 Hz AC-4 |
|
auxiliary contact composition |
1 NO
|
|
overvoltage category |
III
|
|
[Ith] conventional free air thermal current |
20 A (at 50 °C) for power circuit
10 A (at 50 °C) for signalling circuit |
|
Irms rated making capacity |
110 A AC for power circuit conforming to NF C 63-110
110 A AC for power circuit conforming to IEC 60947 110 A AC for signalling circuit conforming to IEC 60947 |
|
rated breaking capacity |
110 A at 415 V conforming to IEC 60947
110 A at 440 V conforming to IEC 60947 80 A at 500 V conforming to IEC 60947 110 A at 220...230 V conforming to IEC 60947 110 A at 380...400 V conforming to IEC 60947 70 A at 660...690 V conforming to IEC 60947 |
|
associated fuse rating |
25 A gG at <= 440 V for power circuit
25 A aM for power circuit 10 A gG for signalling circuit conforming to IEC 60947 10 A gG for signalling circuit conforming to VDE 0660 |
|
average impedance |
3 mOhm - Ith 20 A 50 Hz for power circuit
|
|
insulation resistance |
> 10 MOhm for signalling circuit
|
|
inrush power in VA |
30 VA (at 20 °C)
|
|
hold-in power consumption in VA |
4.5 VA (at 20 °C)
|
|
heat dissipation |
1.3 W
|
|
control circuit voltage limits |
Operational: 0.8...1.15 Uc (at <50 °C)
Drop-out: 0.2...0.75 Uc (at <50 °C) |
|
maximum operating rate |
3600 cyc/h
|
|
auxiliary contacts type |
type instantaneous 1 NO
|
|
signalling circuit frequency |
<= 400 Hz
|
|
minimum switching current |
5 mA for signalling circuit
|
|
minimum switching voltage |
17 V for signalling circuit
|
|
operating time |
10...20 ms coil de-energisation and NO opening
10...20 ms coil energisation and NO closing |
|
safety reliability level |
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1
B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1 |
|
non overlap distance |
0.5 mm
|
|
mechanical robustness |
Shocks contactor closed, on X axis: 10 Gn for 11 ms conforming to IEC 60068-2-27
Shocks contactor closed, on Y axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor closed, on Z axis: 15 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on X axis: 6 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Y axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Shocks contactor opened, on Z axis: 10 Gn for 11 ms conforming to IEC 60068-2-27 Vibrations contactor closed: 4 Gn, 5...300 Hz conforming to IEC 60068-2-6 Vibrations contactor opened: 2 Gn, 5...300 Hz conforming to IEC 60068-2-6 |
|
net weight |
0.18 kg
|
standards |
BS 5424
IEC 60947 NF C 63-110 VDE 0660 |
|
---|---|---|
product certifications |
UL
CSA |
|
protective treatment |
TC conforming to IEC 60068
TC conforming to DIN 50016 |
|
ambient air temperature for storage |
-50…80 °C
|
|
operating altitude |
2000 m without derating
|
|
flame retardance |
V1 conforming to UL 94
Requirement 2 conforming to NF F 16-101 Requirement 2 conforming to NF F 16-102 |
Package 1 Weight |
176 g
|
|
---|---|---|
Package 2 Weight |
9.236 kg
|
Sustainable offer status |
Green Premium product
|
|
---|---|---|
REACh Regulation | ||
REACh free of SVHC |
Yes
|
|
EU RoHS Directive |
Compliant
EU RoHS Declaration |
|
Toxic heavy metal free |
Yes
|
|
Mercury free |
Yes
|
|
RoHS exemption information | ||
China RoHS Regulation |
China RoHS declaration
Pro-active China RoHS declaration (out of China RoHS legal scope) |
|
Environmental Disclosure | ||
Circularity Profile | ||
WEEE |
The product must be disposed on European Union markets following specific waste collection and never end up in rubbish bins
|
Warranty |
18 months
|
---|
Similar products:
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 230 V AC kalem; LC1K0910P7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 230 V AC coil
-
(Out of stock)
3.221,00
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 24 V AC kalem ; LC1K0910B7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NO aux. - 24 V AC coil
-
(Out of stock)
3.221,00
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 6 A - 380...400 V AC kalem ; LC1K0610Q7
TeSys K contactor - 3P - AC-3 <= 440 V 6 A - 1 NO aux. - 380...400 V AC coil
-
(Out of stock)
3.375,00
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 9 A - 380...400 V AC kalem ; LC1K0901Q7
TeSys K contactor - 3P - AC-3 <= 440 V 9 A - 1 NC aux. - 380...400 V AC coil
-
(Out of stock)
3.544,00
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 12 A - 380...400 V AC kalem ; LC1K1210Q7
TeSys K contactor - 3P - AC-3 <= 440 V 12 A - 1 NO aux. - 380...400 V AC coil
-
(Out of stock)
4.052,00
Schneider Electric TeSys K kontaktor - 3P(3 NO) - AC-3 - <= 440 V 16 A - 380...400 V AC kalem ; LC1K1610Q7
TeSys K contactor - 3P - AC-3 <= 440 V 16 A - 1 NO aux. - 380...400 V AC coil
-
(Out of stock)
5.401,00